Alkin Reverse Osmosis Plants are designed and built to deliver water suitable for diverse utilization purposes and various industrial process requirements. They are ideal for small hotels, schools/ institutions, nursing homes, commercial establishments and light industries.
Inclusive of all taxes • Free Shipping
3000 LPH RO System for Commercial, Institutional and Light-Industrial Use
ALKIN Super 3000 is a large-capacity reverse-osmosis plant designed for small hotels, educational institutions, nursing homes, commercial establishments and light industries.
The supplied specifications list a maximum and average flow of 3000 litres per hour, inlet TDS from 500 to 2000 mg/L and permeate TDS below 100 mg/L.
The plant includes 6000 LPH pressure sand and activated carbon filters, antiscalant dosing, a jumbo 5-micron cartridge filter, a 5.2 kW high-pressure pump, an 8 × 40-inch RO membrane and UV treatment.
With listed dimensions of 4000 × 1000 × 1800 mm and an approximate weight of 650 kg, the system requires professional site planning, electrical preparation and commissioning.
Supports high-volume purified-water requirements across suitable facility areas.
Provides centralised purification for large student and staff populations.
Can support suitable pantry, staff and common-area water demand.
Relevant for businesses requiring continuous high-volume purification.
Can be configured for suitable utility and process-water applications.
Supports shared water-distribution systems for high user demand.
The plant uses separate pressure sand and activated carbon filtration stages, each with a listed capacity of 6000 litres per hour.
Pressure sand filtration supports suspended-solid reduction, while activated carbon treatment supports chlorine and organic-compound reduction before RO processing.
The listed high-pressure pump is rated at 6000 LPH and 5.2 kW.
The supplied specification lists an 8 × 40-inch RO membrane.
UV is listed as included in the system specification.
The listed recovery is 30%. Recovery represents the proportion of feed water converted into permeate under the specified operating setup.
Actual recovery, permeate quality and output can vary according to raw-water chemistry, temperature, pressure, membrane condition and plant configuration.
Requires adequate linear plant-room space.
Additional side clearance should be maintained.
Verify vertical clearance before installation.
Install on a stable and load-bearing floor.
Designed for dedicated plant-room environments.
Maintain access for pump, filters and membrane servicing.
The system requires a 415 V AC, three-phase, four-wire, 50 Hz electrical supply according to the supplied technical specification.
Electrical installation, earthing, protection and commissioning should be completed by qualified professionals.
Specifications are presented in equal-width cards so the complete page width is used without a stretched table column.
Model
ALKIN SUPER 3000 / RO-3000
Maximum Flow
3000 LPH
Average Flow
3000 LPH
Inlet TDS
500–2000 mg/L maximum
Permeate TDS
Below 100 mg/L
Recovery
30%
Pressure Sand Filter
6000 LPH
Activated Carbon Filter
6000 LPH
Antiscalant Dosing
Yes
Dosing Tank
50 litres
Micron Cartridge
5-micron jumbo PP, 20 inches long
High-Pressure Pump
6000 LPH, 5.2 kW
RO Membrane
8 × 40 inches
UV
Yes
Plant Dimensions
4000 × 1000 × 1800 mm
Approximate Weight
650 kg
Power Supply
415 V AC, 3 phase, 4 wire, 50 Hz
Applications
Hotels, institutions, nursing homes, commercial establishments and light industries
Designed for high-volume industrial purification.
Listed recovery under specified operating conditions.
Includes large PSF and ACF stages.
Supports the antiscalant dosing arrangement.
Provides high-pressure feed to the RO membrane.
Adds a listed UV treatment stage.
Built for dedicated plant-room installations.
Uses 415 V AC industrial electrical supply.
Relevant for hospitality, education, healthcare and light industry.
The maximum and average listed flow is 3000 LPH.
The supplied specification lists 500–2000 mg/L maximum.
The listed permeate TDS is below 100 mg/L.
The technical specification lists 30% recovery.
The pressure sand filter capacity is listed as 6000 LPH.
The activated carbon filter capacity is listed as 6000 LPH.
Yes. A dosing system and 50-litre tank are listed.
A 5-micron jumbo PP cartridge, 20 inches long, is listed.
The listed pump is 6000 LPH and 5.2 kW.
The listed RO membrane size is 8 × 40 inches.
Yes. UV is listed as included.
The listed dimensions are 4000 × 1000 × 1800 mm.
The supplied specification lists approximately 650 kg.
415 V AC, three phase, four wire and 50 Hz.
Professional industrial installation is strongly recommended.
Yes. Flow, recovery and TDS depend on feed water, temperature, pressure and maintenance.
| Brand | Alkin Water |
| Model | ALKIN SUPER 3000 |
| Capacity | As per variant — contact us for the detailed spec sheet |
Detailed spec sheet for this model isn't in our digital catalog yet — call our team and we'll send it over.
52 Verified Reviews