SUPER 100

110,000.00

INTRODUCTION

Alkin Reverse Osmosis Plants are designed and built to deliver water suitable for diverse utilization purposes and various industrial process requirements. They are ideal for small hotels, schools/ institutions, nursing homes, commercial establishments and light industries.

TECHNICAL SPECIFICATIONS
OPERATING SPECIFICATIONSUNITRO – 100
MAXIMUM FLOWLPH100
AVERAGE FLOWLPH100
INLET TDSMG/L500- 1500 (MAX)
PERMEATE TDSMG/L< 150
RECOVERY%20
SYSTEM SPECIFICATIONSUNITRO – 100
PARTICULATE FILTER10 MICRON, 4” X 20″
ACTIVATED CARBON BLOCK4”X20″
PRESSURE SAND FILTER (PSF) CAPACITYLPH
ACTIVATED CARBON FILTER (ACF) CAPACITYLPH
ANTISCALANT DOSING SYSTEMYES
ANTISCALANT DOSING TANK CAPACITYLITERS20
MICRON CARTRIDGE FILTER (PP)5 MICRON, 20″ LONG
HIGH PRESSURE PUMP (HPP)1000 LPH, 1.1 KW
RO MEMBRANE4″X40″
UVNO
PLANT DIMENSIONS (LXWXHT)MM600 X 800 X 1640
WEIGHT (APPROXIMATELY)KG200
POWER SUPPLY415 V AC, 3 PHASE, 4 WIRE, 50 HZ

Technical specifications are subject to change without prior notice due to continuous product improvement

 

Description

FEATURES

SYSTEM FEATURES

  • Completely assembled / pre-piped / pre-wired
  • Auto start / stop based on water level in the tank
  • MCB for plant protection
  • Raw water pump integrated with plant
  • Microprocessor based control panel for ease of operation and inbuilt process logic
  • Blending cartridge provision to adjust taste / TDS and followed by ultra violet disinfection for total safety
  • Inbuilt protection to high pressure pump by way of low pressure switch / high pressure switch
  • Integrated pre-treatment module for removal of suspended solids along with pressure gauges
  • Robust high pressure pump in SS 304 construction
  • Automatic backwashing of filters available as premium range
  • Online rota-meter for measuring permeate flow
  • Membranes from GE / Hydranautics
  • PU coated MS skid & plated hardware
  • Glycerin filled SS pressure gauges for durability

STANDARD INSTRUMENTATION

  • Pressure Gauges
  • Level Switch
  • Rota Meter
  • Conductivity Meter
  • Pressure Switches

OPTIONS

  • Automatic backwashing of filters
  • pH correction system
  • Post UV system
  • Cleaning system
  • Post treatment system
  • Remote monitoring system

RAW WATER CHARACTERISTICS

  • Hardness: 200-500 ppm
  • Alkalinity: 200-300 ppm
  • Chlorides: 300-400 ppm
  • Nitrates: 20-40 ppm
  • Silica: 10-15 ppm
  • Total Dissolved Solids (TDS): 500-2000 ppm (max)

LIMITING CONDITIONS FOR RO FEED WATER

  • Turbidity: < 5 NTU
  • Organics: Nil
  • Maximum Water Temperature: < 40° C
  • Iron: < 0.3 ppm
  • Fluoride: < 1 ppm
  • Silt Density Index (SDI): < 5 ppm
  • Oil & Grease: Nil
  • Free Chlorine: Nil

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.